LinteL ARNS-20 Automatic fractional petroleum and petroleum product content tester
LinteL ARNS-20
Automatic fractional petroleum and petroleum product content tester
Standards implemented
GOST 2177 (methods A and B)
GOST R EN ISO 3405-2007
ASTM D 86
Part number:
Description
Preinstalled test programs. Each test program contains test standard, group, parameters and report form. Thus, when program selected, all necessary parameters and test conditions are set and maintained automatically
Report form editor allows to set the required points and define if it is required to make corrections for barometric pressure and losses
Automatic recording of initial and final boiling point, decomposition temperature, dry point temperature (by pressing the button), percentage of stripping (vaporation), losses and residue
Possibility to connect an external thermocryostat (for example, LinteL TKS-20) to maintain the bath and receiver temperature automatically for groups below group 4
Integration with LinteL Link Data Collection System enables collection and transfer of laboratory test results from the tester to a personal computer via wireless communication. Integration with the laboratory information system Lintel LIS, provides a comprehensive automation of laboratory activities
Automatic correction for barometric pressure
Heating termination after recording of final boiling point, decomposition, dry point
Automatic cooling of the heater at the distillation completion with the heater cooling up to the temperature of 5 ºC above ambient temperature
Report form editor allows to set the required points and define if it is required to make corrections for barometric pressure and losses
Automatic recording of initial and final boiling point, decomposition temperature, dry point temperature (by pressing the button), percentage of stripping (vaporation), losses and residue
Possibility to connect an external thermocryostat (for example, LinteL TKS-20) to maintain the bath and receiver temperature automatically for groups below group 4
Integration with LinteL Link Data Collection System enables collection and transfer of laboratory test results from the tester to a personal computer via wireless communication. Integration with the laboratory information system Lintel LIS, provides a comprehensive automation of laboratory activities
Automatic correction for barometric pressure
Heating termination after recording of final boiling point, decomposition, dry point
Automatic cooling of the heater at the distillation completion with the heater cooling up to the temperature of 5 ºC above ambient temperature