Description

The instrument can be used for the adjustment of the measuring voltage transformers, control and measurement of the signals when producing and metering the electricity. The instrument is produced in two versions: - Portable (P); - Stationary (ST). The kilovoltmeter measuring unit power supply is carried out with the help of the battery: - Voltage – 6 V; - Capacity – 1.5 A/h.

Direct current voltage measurement range, kV 0,1…100
Direct current voltage (with the frequency of 50 Hz) effective values measurement range, kV 0,1…100
Direct current voltage (with the frequency of 50 Hz) crest values measurement range, kV 0,1…140
Voltage divider input capacity, max, pF 100
Voltage divider active input resistance, MO 260
Voltage divider division factor 1/10,000
Maximum basic conventional error, % ± 0,5/± 0,25